Gilmore-Kramer Company Material Handling Equipment - 1-800-544-3137 - Service - Installation - Custom Fabrication
Home Order Search Quote Info About Us My Account Shopping Cart
    Categories
Back to Product Category

HEAVY DUTY ALUMINUM CROSSOVER BRIDGE
1,000 LBS. CAPACITY

IBC INDUSTRIAL DESIGN SHOWN ABOVE
STRONG-ATTRACTIVE-WEATHER RESISTANT
Acceptable Usage: For industrial/commercial maintenance access and industrial/commercial storage access.

• Quality engineered to your specific height requirements
• Designed for safety and convenience
Heavy duty aluminum I bar grating stair treads won’t sag or dish (supplied as standard).
• Factory welded handrails of 1 1/2" x .125 square tubing.
• 2 rail system with toeguard (standard).
10" x 2.6" aluminum (6061-T6511) structural channel stringers.
• Structural connections are made with 5/8" dia. Bolts and 3/8" butt    plates.
• Fire proof construction.
• Available in 2 tread widths.
• Meets OSHA requirements. See OSHA standard 1910.25 (Fixed Industrial Stairs) listed below price table.
• Standard mill finish aluminum.
• Provides safe walkways over conveyors, pipes and other obstacles.
• Choose 36" or 48" tread width - special sizes available upon request.
• Overall width = tread width + 5.25".
• Stainless Steel assembly hardware included.

STAIR SECTIONS AVAILABLE IN 2 STYLES
33° ANGLE AND 10 15/16" DEEP TREADS
45° ANGLE AND
9 13/16" DEEP TREADS
CUSTOM SIZES - SAME DAY QUOTES
Custom sizes and configurations are readily available. We provide same day price quotes if you require a special
stair angle, specific tread rise/run, or a maximum horizontal stair run to satisfy available floor space constraints.

Aluminum I Bar Grating with Stainless Steel
Assembly Hardware Treads provided with
corrugated aluminum nosing.
Top View of 45 Deg. Rail
Top View of 32 Deg. Rail
Rugged heavy duty industrial grade construction

When ordering BOCA or OSHA, please add a B for BOCA in
front of the Model No. If OSHA, please add an O in front of
the Model No. Example: (B-2424-BG or O-2424-BG).
Also Note: Any specific underclearance is available. Price as
next highest in the table and specify on order.

Structural connections with 5/8" dia. Bolts
and 3/8" butt plates.

Order Online, by Phone, or by E-Mail

~ Add items to your online shopping cart ~
Click a Price of the item you wish to purchase.


PRICES
MODEL NO. UNDER
CLEARANCE
SPAN TREAD
WIDTH
OSHA
HORIZONTAL
RUN (In.)
BOCA
HORIZONTAL
RUN (In.)
OSHA PRICE
LIST
BOCA PRICE
LIST
2424-BG-36-AL
24 24 36
82 1/8
140 15/16
2424-BG-48-AL
24 24 48
82 1/8
140 15/16
2436-BG-36-AL
24 36 36
94 1/8
152 15/16
2436-BG-48-AL
24 36 48
94 1/8
152 15/16
2448-BG-36-AL
24 48 36
106 1/8
164 15/16
2448-BG-48-AL
24 48 48
106 1/8
164 15/16
3624-BG-36-AL
36 24 36
101  1/8
184 15/16
3624-BG-48-AL
36 24 48
101  1/8
184 15/16
3636-BG-36-AL
36 36 36
113  1/8
196 15/16
3636-BG-48-AL
36 36 48
113  1/8
196 15/16
3648-BG-36-AL
36 48 36
125  1/8
208 15/16
3648-BG-48-AL
36 48 48
125  1/8
208 15/16
4824-BG-36-AL
48 24 36
139 1/8
229 15/16
4824-BG-48-AL
48 24 48
139 1/8
229 15/16
4836-BG-36-AL
48 36 36
151 1/8
241 15/16
4836-BG-48-AL
48 36 48
151 1/8
241 15/16
4848-BG-36-AL
48 48 36
163 1/8
253 15/16
4848-BG-48-AL
48 48 48
163 1/8
253 15/16
6024-BG-36-AL
60 24 36
158 1/8
249 13/16
6024-BG-48-AL
60 24 48
158 1/8
249 13/16
6036-BG-36-AL
60 36 36
170 1/8
261 13/16
6036-BG-48-AL
60 36 48
170 1/8
261 13/16
6048-BG-36-AL
60 48 36
182 1/8
273 13/16
6048-BG-48-AL
60 48 48
182 1/8
273 13/16
7224-BG-36-AL
72 24 36
172  5/16
295  7/8
7224-BG-48-AL
72 24 48
172  5/16
295  7/8
7236-BG-36-AL
72 36 36
184  5/16
307  7/8
7236-BG-48-AL
72 36 48
184  5/16
307  7/8
7248-BG-36-AL
72 48 36
196  5/16
319  7/8
7248-BG-48-AL
72 48 48
196  5/16
319  7/8
8424-BG-36-AL
84 24 36
191 1/2
340  3/16
8424-BG-48-AL
84 24 48
191 1/2
340  3/16
8436-BG-36-AL
84 36 36
203 1/2
352  3/16
8436-BG-48-AL
84 36 48
203 1/2
352  3/16
8448-BG-36-AL
84 48 36
215 1/2
364  3/16
8448-BG-48-AL
84 48 48
215 1/2
364  3/16

ALUMINUM CROSSOVER BRIDGE
Asymetrical crossover

OSHA STANDARD 1910.25 STAIRWAYS
Walking-Working Surfaces and Personal Fall Protection Systems Final Rule
Frequently Asked Questions
The intent of OSHA’s Walking-Working Surfaces standard, 29 CFR Part 1910, Subpart D & I, is to increase the
protection of general industry employees and employers from hazards associated with walking-working surfaces. The
rule making will significantly reduce the number of worker deaths and injuries that occur each year resulting from
workplace slip, trip, and fall hazards. The final rule was published on November 18, 2016, and became effective on
January 17, 2017. Some requirements in the final rule have compliance dates after the effective date and will be
discussed in further detail below. This final rule and the associated preamble, providing more detailed explanation of
the rule, is available on the Federal Register website at 81 FR 82494, Walking-Working Surfaces; Personal Protective
Equipment; Final Rule, November 18, 2016.
OSHA requirements are set by statute, standards, and regulations. The Agency’s interpretations explain these require-
ments and how they apply to particular circumstances, but they do not create additional employer obligations. Note
that our enforcement guidance may be affected by legislative or rule making changes to OSHA requirements. Also,
from time to time we update our guidance in response to new information. To keep apprised of such developments,
you can consult OSHA’s website at http://www.osha.gov.
This webpage provides guidance, in a question and answer format, regarding OSHA’s Final Rule, Walking-Working
Surfaces and Personal Protective Equipment, 29 CFR Part 1910, Subpart D and I. These Frequently Asked Questions
(FAQs) are divided into five sections: general questions, rope descent system (RDS) questions, outdoor advertising
questions, residential roof questions, and agricultural operation questions.
Standard Stairs
Does the exception to the 9.5-inch riser height and 9.5-inch tread depth requirements for stairs installed before
January 17, 2017 (§19210.25(c)(5)), also apply to stairs designed and fabricated, but not yet installed, by that date?
Stairs with design drawings issued for construction or that were in fabrication before January 17, 2017, but not
installed, will be in compliance if they met the previous requirements for standard stairs.
Under the previous standard, stairs with a handrail that doubles as a stair rail could have a rail height of 30 to 34
inches. If an employer's stairs were installed prior to January 17, 2017, must the rails have a minimum height of
36 inches if the stair rail doubles as a handrail?
The final rule does not affect stair rail systems and handrails installed before January 17, 2017 that were in com-
pliance with the requirements in the old standard.
Does the requirement that standard stairs have a slope between 30 to 50 degrees apply to stairs installed after January
7, 2017. Therefore, the maximum angle for standard stairs is 45 degrees.
Yes. The final rule limits the maximum rise height and minimum tread depth to 9.5 inches for standard stairs installed
after January 17, 2017. Therefore, the maximum angle for standard stairs is 45 degrees.
Are stairs installed after January 17, 2017, that have an angle of 50 degrees considered to be ships stairs?
The final rule defines ship stairs as “a stairway that is equipped with treads, stair rails, and open risers, and has a slope
of 50 to 70 degrees.” Ship stairs must also comply with §1910.25(b) and (e), such as a minimum tread depth of 4
inches, a minimum tread width of 18 inches, and a vertical clearance above any stair tread to any overhead
obstruction of at least 6 feet 8 inches.
What if the doorway described in §1910.25(b)(5)(ii) and shown in figure D-7 is perpendicular to the direction of
travel and opens onto the landing? Does the same dimension apply to this condition?
Yes. As figure D-7 illustrates, Section 1910.25(b)(5) requires that a platform be provided when a door or a gate opens
directly onto a stairway. For platforms installed after January 17, 2017, the final rule also requires that employers
ensure the swing of the door or gate does not reduce the "effective usable depth" of the platform to less than 22 inches (§1910.25(b)(5)(ii)). The preamble to the final rule describes “effective usable depth” as the portion of the platform
beyond the swing of the door where a worker can stand when opening the door (82 FR 82557). The provision applies
equally to stairway doors that are perpendicular to the direction of travel.
Are fixed stairs attached to the exterior of tanks required to comply with the requirements of §1910.25(b) or would
those stairs fall under the exemptions in §1910.25(a)?

The exception from the stair requirements in §1910.25(a) only applies to stairs serving floating roof tanks, stairs on
scaffolds, stairs on self-propelled motorized equipment, or stairs designed into machines or equipment. For stairs on
the exterior of other tanks, employers would have to ensure they comply with the requirements in §1910.25(b) and (c).
Would winding stairs attached to tanks be required to meet the requirements in §1910.25(d) for spiral stairs?
No. Section 1910.21(b) defines spiral stairs as a "series of treads attached to a vertical pole in a winding fashion,
usually within a cylindrical space" (emphasis added). Winding stairs attached to tanks do not have vertical poles;
therefore, they are not spiral stairs and must meet the requirements of §1910.25(b) and (c).
Based on the height requirements for stair rails and handrails and the requirements in Table D-2, are both stair rails
and handrails required on stairs that have two open sides and are less than 44-in. wide?

Yes. Section 1910.28(b)(11)(ii) Table D-2 contains a printing error, which OSHA will correct in a published notice.
For each flight of stairs with two open sides and a width of less than 44 inches, column 4 of Table D-2 should state
"One stair rail system with hand rail on each open side" is required. (See 81 FR 82611-12).
Steel Crossover Bridge, Stair Sections, Specific Height Requirements, Bar Grating Stair Treads, Welded Handrails,
Structural Channel Stringers, Walkways Over Conveyors, Galvanized Finish, BOCA Design 33°, and OSHA Design
45° from your source for material handling equipment.

Back to Product Category
Home - Order - Search - Quote- Info - About Us - My Account - Shopping Cart