Back to Product Category
TRENCH
BRACES
|
SE
& BE SERIES |
|
|
|
|
|
Adjustable Range..................................................
7 - 10 in.
Pipe Size ..............................................................
1.5 - 2 in.
Lever Length ......................................................... 9.5
- 11 in. |
|
|
|
Provides
an efficient, economical protection against cave-ins
and costly re-digging in construction & maintenance.
Ball socket joints tilt for added safety on angular mounting.
Holes on each end facilitates mounting to wood members. |
|
|
|
Trench braces
are designed for use with standard schedule
40 pipe. Screw end models SE12, SE16 and butt end
model BE25 use 1.5 diameter pipe. Model SE18 and
butt end BE35 use 2 diameter pipe. Pipe should be cut
to length based on the chart below and drawing in Fig. 1. |
|
|
|
|
|
|
|
|
|
SE
Series Trench Braces are used to shore up the walls of
this trench for the repair work of underground water pipes. |
|
|
|
|
|
|
|
Order
Online, by Phone, or by E-Mail |
|
|
|
~ Add
items to your online shopping cart ~
Click the Model No. of the item you wish
to purchase. |
|
|
|
PRICES |
Model
No. |
Adjust
Range
(in) |
Price |
Pipe
Size
(in) |
Model No.
Butt End |
"A" Min.
Pipe Length
(in) |
"B" Min.
Closed Ht.
(in) |
Price |
SE-12 |
7 |
$170.20 |
1 1/2 |
BE-25 |
12 |
18 |
$79.35 |
SE-16 |
10 |
$178.25 |
16 |
22 |
SE-18 |
$293.25 |
2 |
BE-35 |
18 |
25 1/2 |
$108.10 |
|
Dimensions
assume the use of both screw & butt ends together as an assembly. |
|
Model
(Screw
End) |
Adjust
Range
(in) |
Pipe
Size
(in) |
Dimensions
( in) |
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
L |
Min. Pipe
Length |
Width |
Length |
Lever
Width |
Lever
Dia.
O.D. |
Lever
Length |
Lever
Height |
Lever
Nut
Height |
Screw
Dia.
O.D. |
Height |
I.D. Butt
End
Height |
Collar
Height |
SE12 |
7 |
1.5 |
12 |
2.44 |
5.75 |
1.25 |
2.13 |
9.5 |
.68 |
1.13 |
1.38 |
2.44 |
---- |
---- |
SE16 |
10 |
1.5 |
16 |
2.44 |
5.75 |
1.25 |
2.13 |
9.5 |
.68 |
1.13 |
1.38 |
2.44 |
---- |
---- |
SE18 |
10 |
2 |
18 |
2.75 |
7.5 |
1.5 |
2.68 |
11 |
.81 |
1.38 |
1.87 |
3 |
---- |
---- |
Model
(Butt
End) |
Screw
Ends
to be used
with Butt End |
|
BE25 |
SE12 / SE16 |
---- |
2.44 |
---- |
---- |
---- |
---- |
---- |
---- |
---- |
---- |
1.5 |
3.87 |
BE35 |
SE18 |
---- |
2.75 |
---- |
---- |
---- |
---- |
---- |
---- |
---- |
---- |
1.93 |
4.87 |
|
|
|
|
Quick
Reference Timber/Trench Brace Equivalency Tables* |
The
following charts are based on OSHA Timber/Trench Brace Charts* which do
not consider transverse
loading conditions. |
|
|
Soil
Type A |
Pa = 25 x H + 72 psf (2ft.
Surcharge) |
Trench Depth
(ft) |
Horizontal Spacing
(ft) |
Cross Brace |
Wales |
Uprights (in) |
Width of
Trench (ft) |
Vertical
Spacing (ft) |
Size
(in) |
Vertical Spacing (ft) |
Max. Allowable
Horizontal Spacing (Ft) |
up to 4 |
up to 6 |
up to 8 |
4
|
Not Req. |
4' |
5' |
6' |
8' |
5
to
10
|
up to 6 |
SE12 |
SE12 |
SE18 |
|
|
2"x6" |
|
SE16 |
SE16 |
up to 8 |
SE12 |
SE12 |
SE18 |
|
|
|
2"x6" |
SE16 |
SE16 |
up to 10 |
SE18 |
SE18 |
SE18 |
8 x 8 |
4 |
|
2"x6" |
|
|
up
to 12 |
SE18 |
SE18 |
|
|
|
2"x6" |
|
10
to
15 |
up to 6 |
SE12 |
SE12 |
SE18 |
Not Req. |
|
|
3"x8" |
|
SE16 |
SE16 |
up
to 8 |
SE18 |
SE18 |
|
8 x 8 |
4 |
2"x6" |
|
|
|
|
|
|
Soil
Type B |
Pa = 45 x H + 72 psf (2ft.
Surcharge) |
Trench
Depth
(ft) |
Horizontal
Spacing
(ft) |
Cross Brace |
Wales |
|
Uprights (in) |
Width of
Trench (ft) |
Vertical
Spacing
(ft) |
Size
(in) |
Vertical
Spacing (ft) |
Max. Allowable Horizontal
Spacing (Ft) |
up to 4 |
up to 6 |
3' |
5
to
10 |
up
to
6 |
SE-18 |
SE-18 |
5 |
6 x 8 |
5 |
2"x6" |
|
*Refer
to OSHA Standard, 29CRF 1926, subpart P-Excavations (tables C-1.1 &
C-1.2). |
|
Mechanical Jacks, Screw Jack,
Screw Jacks, Trench Braces, Trench Brace, Mechanical Jack, Simplex Jack,
Simplex
Jacks, and Templeton Kenly from your complete source for material handling
equipment. |
Back to Product Category
|