LoPro Commercial Series Air Curtains Electric Heated
|
|
The Most Cost-effective Environmental and Sanitation Barrier Youll Never See
|
|
FREE FREIGHT
|
| FOR ALL AIR CURTAINS SHIPPED TO LOCATIONS WITHIN THE 48 CONTIGUOUS UNITED STATES |
|
 |
|
|
|
| The Most Cost-Effective Environmental and Sanitation Barrier You'll Never See |
|
|
|
| AIR CURTAIN BENEFITS |
|
LOPRO COMMERCIAL AIR CURTAINS SERIES FEATURES |
• Reduces Energy Costs And Consumption • Creates Effective Environmental Separation • Maintains Interior Building Temperatures • Provides Low Operational Costs • Minimizes Dirt, Dust, And Fumes • Prevents Flying Insects From Intruding • Offers An Unobstructed View, Enhancing Safety |
|
|
• Aesthetically Pleasing "Low Profile" 8" Design • Low Noise Level For Quiet Operation • Easy To Install • Low Maintenance • NSF Models Available (Contact us.) |
|
|
|
DOOR HEIGHTS |
|
|
| DOOR WIDTHS |
|
|
Environmental Separation up to 8' Flying Insect Control up to 7' |
| 25" to 144" |
|
|
|
|
|
|
| HEATING OPTIONS |
|
|
| Electric and Steam/Hot Water |
|
|
|
|
|
|
|
 |
 |
|
|
|
|
|
Model No.
|
Width of Door
|
Door Height
|
FLA (Ampacity) Single Phase
|
Sound dBA
|
Weight (lbs)
|
|
115V
|
208V/230V
|
|
LPV36
|
36"
|
7' - 8'
|
2.4
|
1.2 /1.2
|
49
|
30
|
|
LPV42
|
42"
|
7' - 8'
|
2.4
|
1.2/1.2
|
50
|
33
|
|
LPV48
|
48"
|
7' - 8'
|
2.4
|
1.2/1.2
|
52
|
37
|
|
LPV60
|
60"
|
7' - 8'
|
2.6
|
1.4/1.4
|
53
|
45
|
|
LPV72
|
72"
|
7' - 8'
|
2.6
|
1.4/1.4
|
53
|
56
|
|
LPV84-2
|
84"
|
7' - 8'
|
4.8
|
2.4/2.4
|
53
|
66
|
|
LPV96-2
|
96"
|
7' - 8'
|
4.8
|
2.4/2.4
|
53
|
74
|
|
LPV108-2
|
108"
|
7' - 8'
|
5
|
2.6/2.6
|
54
|
82
|
|
LPV120-2
|
144"
|
7' - 8'
|
5.2
|
2.6/2.6
|
54
|
90
|
|
LPV144-2
|
144"
|
7' - 8'
|
5.2
|
2.8/2.8
|
54
|
112
|
|
|
|
LOPRO (LPV) 1/6 HP VARIABLE SPEED ELECTRIC HEATED COMMERCIAL MODELS
|
|
|
|
|
|
 |
|
NOTES: |
|
1. This product is designed to meet the National Electric Code (NEC) and is ETL Listed for the US and Canada. |
|
2. Continuous duty, direct drive, variable speed, double shaft motors with automatic thermal overload protection. Overload protects motor from burnout, minimizing maintenance costs. |
|
3. Blower wheels are rust proof and dynamically balanced to provide quiet operation, while maintaining high air velocity. |
|
4. Low profile appearance. Overall height is 8" and overall depth is 11 3/4". |
|
5. Air directional vanes, with 40° sweep front to back, compensates for drafts. |
|
6. Mounted adjustable speed controller knob allows air velocity to meet a wide range of field conditions. Units greater than 72" are double units joined with a 2" mounting bracket located in the center, field installed. The speed controller will be located on the right hand unit and controls both units. |
|
7. All units have a self contained one piece cabinet, fire retardant and corrosion proof point lock metal, double protected with Obsidian Black rust preventative electro- static powder coating . |
|
|
|
|
|
|
|
|
8. Normally closed door limit switch(es) is optional and field installed. Switch to be mounted so the air curtain turns on as the door begins to open. |
|
 |
|
|
|
|
|
9. Units greater than 72" require dual power supplies, one for each air curtain. |
|
|
|
|
|
| Model No. |
Unit Length (A) |
| LPV236-1E |
36" |
| LPV242-1E |
42" |
| LPV248-1E |
48" |
| LPV260-1E |
60" |
| LPV272-1E |
72" |
| LPV284-2E |
86" |
| LPV296-2E |
98" |
| LPV2108-2E |
110" |
| LPV2120-2E |
122" |
| LPV2144-2E |
146" |
|
|
|
|
TYPICAL INSTALLATION
|
|
|
1- lnstall Mounting plate(s) using the pre-drilled holes. |
|
|
2 - Securely attach cabinet to mounting plate using tabs as guides, when fully inserted secure with (2) #10 Tek Screws. "CAUTION": Unit to be mounted with the lowest moving part at least 7 Feet above floor or grade level. |
|
|
3 - lnstall optional door limit switch(es) to door header. (8) |
|
|
4 - Connect internal wires from unit to supply power. |
|
|
|
|
|
|
|
|
|
Understanding Series Order Codes
|
 |
|
| Standard Features: |
|
|
| • Easy Install Mounting Plate |
|
| • 18 month warranty |
|
| • 1/6 HP Direct Drive |
|
| • Made in USA |
|
| • Variable Speed Controller |
|
|
|
| • 8" Low Profile Metal Design |
Protection |
|
| • Standard color: |
• Environmental: 8' |
|
|
 |
|
|
• Flying Insect: 7' |
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
Click the button of the item you wish to purchase. Contact us for special lengths
|
PRICING FOR LOPRO (LPV) VARIABLE SPEED COMMERCIAL ELECTRIC HEATED MODELS
|
|
Model No. - Color Code (std)
|
Voltage
|
kW
|
Air Volume (max.)
|
Length
|
Height
|
Depth
|
Full Load Draw
|
Heater Draw
|
Motor Draw
|
Avg. Velocity
|
Weight (lbs.)
|
Price
|
|
|
208/1/60
|
6.1kW
|
900cfm
|
36"
|
8"
|
11 3/4"
|
31amps
|
~
|
~
|
1800fpm
|
35
|
$2,920.50
|
|
|
230/1/60
|
6.1kW
|
900cfm
|
36"
|
8"
|
11 3/4"
|
28amps
|
~
|
~
|
1800fpm
|
35
|
$2,920.50
|
|
|
208/3/60
|
10kW
|
900cfm
|
36"
|
8"
|
11 3/4"
|
29amps
|
~
|
~
|
1800fpm
|
35
|
$2,920.50
|
|
|
230/3/60
|
10kW
|
900cfm
|
36"
|
8"
|
11 3/4"
|
26amps
|
~
|
~
|
1800fpm
|
35
|
$2,920.50
|
|
|
460/3/60
|
10kW
|
900cfm
|
36"
|
8"
|
11 3/4"
|
~
|
13amps
|
2.4amps
|
1800fpm
|
35
|
$2,920.50
|
|
|
460/3/60
|
10kW
|
900cfm
|
36"
|
8"
|
11 3/4"
|
~
|
13amps
|
1.2amps
|
1800fpm
|
35
|
$2,920.50
|
|
|
208/1/60
|
8kW
|
1050cfm
|
42"
|
8"
|
11 3/4"
|
40amps
|
~
|
~
|
1800fpm
|
40
|
$3,047.00
|
|
|
230/1/60
|
8kW
|
1050cfm
|
42"
|
8"
|
11 3/4"
|
36amps
|
~
|
~
|
1800fpm
|
40
|
$3,047.00
|
|
|
208/3/60
|
10kW
|
1050cfm
|
42"
|
8"
|
11 3/4"
|
29amps
|
~
|
~
|
1800fpm
|
40
|
$3,047.00
|
|
|
230/3/60
|
10kW
|
1050cfm
|
42"
|
8"
|
11 3/4"
|
26amps
|
~
|
~
|
1800fpm
|
40
|
$3,047.00
|
|
|
460/3/60
|
10kW
|
1050cfm
|
42"
|
8"
|
11 3/4"
|
~
|
13amps
|
2.4amps
|
1800fpm
|
40
|
$3,047.00
|
|
|
460/3/60
|
10kW
|
1050cfm
|
42"
|
8"
|
11 3/4"
|
~
|
13amps
|
1.2amps
|
1800fpm
|
40
|
$3,047.00
|
|
|
208/1/60
|
8kW
|
1200cfm
|
48"
|
8"
|
11 3/4"
|
40amps
|
~
|
~
|
1800fpm
|
45
|
$3,108.60
|
|
|
230/1/60
|
8kW
|
1200cfm
|
48"
|
8"
|
11 3/4"
|
36amps
|
~
|
~
|
1800fpm
|
45
|
$3,108.60
|
|
|
208/3/60
|
13kW
|
1200cfm
|
48"
|
8"
|
11 3/4"
|
37amps
|
~
|
~
|
1800fpm
|
45
|
$3,108.60
|
|
|
230/3/60
|
13kW
|
1200cfm
|
48"
|
8"
|
11 3/4"
|
34amps
|
~
|
~
|
1800fpm
|
45
|
$3,108.60
|
|
|
460/3/60
|
13kW
|
1200cfm
|
48"
|
8"
|
11 3/4"
|
~
|
16amps
|
2.4amps
|
1800fpm
|
45
|
$3,108.60
|
|
|
460/3/60
|
13kW
|
1200cfm
|
48"
|
8"
|
11 3/4"
|
~
|
16amps
|
1.2amps
|
1800fpm
|
45
|
$3,108.60
|
|
|
208/1/60
|
9.5kW
|
1500cfm
|
60"
|
8"
|
11 3/4"
|
47amps
|
~
|
~
|
1800fpm
|
50
|
$3,193.30
|
|
|
230/1/60
|
9.5kW
|
1500cfm
|
60"
|
8"
|
11 3/4"
|
43amps
|
~
|
~
|
1800fpm
|
50
|
$3,193.30
|
|
|
208/3/60
|
13kW
|
1500cfm
|
60"
|
8"
|
11 3/4"
|
37amps
|
~
|
~
|
1800fpm
|
50
|
$3,193.30
|
|
|
230/3/60
|
13kW
|
1500cfm
|
60"
|
8"
|
11 3/4"
|
34amps
|
~
|
~
|
1800fpm
|
50
|
$3,193.30
|
|
|
460/3/60
|
13kW
|
1500cfm
|
60"
|
8"
|
11 3/4"
|
~
|
16amps
|
2.6amps
|
1800fpm
|
50
|
$3,193.30
|
|
|
460/3/60
|
13kW
|
1500cfm
|
60"
|
8"
|
11 3/4"
|
~
|
16amps
|
1.4amps
|
1800fpm
|
50
|
$3,193.30
|
|
|
208/1/60
|
9.5kW
|
1800cfm
|
72"
|
8"
|
11 3/4"
|
47amps
|
~
|
~
|
1800fpm
|
56
|
$3,319.80
|
|
|
230/1/60
|
9.5kW
|
1800cfm
|
72"
|
8"
|
11 3/4"
|
43amps
|
~
|
~
|
1800fpm
|
56
|
$3,319.80
|
|
|
208/3/60
|
13kW
|
1800cfm
|
72"
|
8"
|
11 3/4"
|
37amps
|
~
|
~
|
1800fpm
|
56
|
$3,319.80
|
|
|
230/3/60
|
13kW
|
1800cfm
|
72"
|
8"
|
11 3/4"
|
34amps
|
~
|
~
|
1800fpm
|
56
|
$3,319.80
|
|
|
460/3/60
|
13kW
|
1800cfm
|
72"
|
8"
|
11 3/4"
|
~
|
16amps
|
2.6amps
|
1800fpm
|
56
|
$3,319.80
|
|
|
460/3/60
|
13kW
|
1800cfm
|
72"
|
8"
|
11 3/4"
|
~
|
16amps
|
1.4amps
|
1800fpm
|
56
|
$3,319.80
|
|
|
Model No. - Color Code (std)
|
Voltage
|
kW
|
Air Volume (max.)
|
Length
|
Height
|
Depth
|
Full Load Draw
|
Heater Draw
|
Motor Draw
|
Avg. Velocity
|
Weight (lbs.)
|
Price
|
|
|
208/3/60
|
20kW
|
2100cfm
|
84"
|
8"
|
11 3/4"
|
58amps
|
~
|
~
|
1800fpm
|
76
|
$4,710.20
|
|
|
230/3/60
|
20kW
|
2100cfm
|
84"
|
8"
|
11 3/4"
|
53amps
|
~
|
~
|
1800fpm
|
76
|
$4,710.20
|
|
|
460/3/60
|
20kW
|
2100cfm
|
84"
|
8"
|
11 3/4"
|
~
|
25amps
|
4.8amps
|
1800fpm
|
76
|
$4,710.20
|
|
|
460/3/60
|
20kW
|
2100cfm
|
84"
|
8"
|
11 3/4"
|
~
|
25amps
|
2.4amps
|
1800fpm
|
76
|
$4,710.20
|
|
|
208/3/60
|
26kW
|
2400cfm
|
96"
|
8"
|
11 3/4"
|
75amps
|
~
|
~
|
1800fpm
|
86
|
$5,138.10
|
|
|
230/3/60
|
26kW
|
2400cfm
|
96"
|
8"
|
11 3/4"
|
68amps
|
~
|
~
|
1800fpm
|
86
|
$5,138.10
|
|
|
460/3/60
|
26kW
|
2400cfm
|
96"
|
8"
|
11 3/4"
|
~
|
33amps
|
4.8amps
|
1800fpm
|
86
|
$5,138.10
|
|
|
460/3/60
|
26kW
|
2400cfm
|
96"
|
8"
|
11 3/4"
|
~
|
33amps
|
2.4amps
|
1800fpm
|
86
|
$5,138.10
|
|
|
208/3/60
|
26kW
|
2700cfm
|
108"
|
8"
|
11 3/4"
|
75amps
|
~
|
~
|
1800fpm
|
88
|
$5,567.10
|
|
|
230/3/60
|
26kW
|
2700cfm
|
108"
|
8"
|
11 3/4"
|
68amps
|
~
|
~
|
1800fpm
|
88
|
$5,567.10
|
|
|
460/3/60
|
26kW
|
2700cfm
|
108"
|
8"
|
11 3/4"
|
~
|
33amps
|
5amps
|
1800fpm
|
88
|
$5,567.10
|
|
|
460/3/60
|
26kW
|
2700cfm
|
108"
|
8"
|
11 3/4"
|
~
|
33amps
|
2.6amps
|
1800fpm
|
88
|
$5,567.10
|
|
|
208/3/60
|
26kW
|
3000cfm
|
120"
|
8"
|
11 3/4"
|
75amps
|
~
|
~
|
1800fpm
|
95
|
$5,995.00
|
|
|
230/3/60
|
26kW
|
3000cfm
|
120"
|
8"
|
11 3/4"
|
68amps
|
~
|
~
|
1800fpm
|
95
|
$5,995.00
|
|
|
460/3/60
|
26kW
|
3000cfm
|
120"
|
8"
|
11 3/4"
|
~
|
33amps
|
5.2amps
|
1800fpm
|
95
|
$5,995.00
|
|
|
460/3/60
|
26kW
|
3000cfm
|
120"
|
8"
|
11 3/4"
|
~
|
33amps
|
2.8amps
|
1800fpm
|
95
|
$5,995.00
|
|
|
208/3/60
|
26kW
|
3600cfm
|
144"
|
8"
|
11 3/4"
|
75amps
|
~
|
~
|
1800fpm
|
110
|
$6,422.90
|
|
|
230/3/60
|
26kW
|
3600cfm
|
144"
|
8"
|
11 3/4"
|
68amps
|
~
|
~
|
1800fpm
|
110
|
$6,422.90
|
|
|
460/3/60
|
26kW
|
3600cfm
|
144"
|
8"
|
11 3/4"
|
~
|
33amps
|
5.2ams
|
1800fpm
|
110
|
$6,422.90
|
|
|
460/3/60
|
26kW
|
3600cfm
|
144"
|
8"
|
11 3/4"
|
~
|
33amps
|
2.8amps
|
1800fpm
|
110
|
$6,422.90
|
|
Note: A separate 115v or 208v power source required for motors. O= 460/8/60, 115/1/60 P= 460/3/60, 208/1/60 |
|
 |
|
OB
|
|
TS
|
|
PW
|
|
|
|
|
|
|
|
|
| Optional Color Available - Std. Production Color is Obsidian Black (matte) See add-on prices below. |
|
|
|
|
|
|
|
|
Prices for Colors That are not Standard for the Series (add these prices to price of Electric Heated Lopro Comm. air curtain above)
|
| Length of Unit |
25" |
36" |
42" |
48" |
60" |
64" |
72" |
84" |
96" |
108" |
120" |
144" |
| TS |
|
|
|
|
|
|
|
|
|
|
|
|
| PW |
|
|
|
|
|
|
|
|
|
|
|
|
|
Click the button of the item you wish to purchase. Contact us for special lengths
|
|
LOPRO ACCESSORIES - ELECTRIC HEATEAD
|
| DOOR SWITCHES |
| Automatic on/off control of air curtain as door is opened and closed |
| LINE VOLTAGE |
| Part # |
Package |
Price |
| 99-014 |
Steel Mechanical Universal Surface-Mounted Plunger/Roller Switch |
$168.19 |
| 24 VOLT CONTROL |
| Part # |
Package |
Price |
| 99-018 |
Commercial Magnetic Reed Switch Only Plastic • Surface-mounted NOTE: Used with control packages J0023 or J0024 for double doors |
$78.43 |
| CONTROL PACKAGES - Combination packages of door switches, controllers, time delays, and thermostats |
| LINE VOLTAGE |
| Part # |
Package |
Price |
|
|
Analog Thermostat Remote-mounted |
$196.13
|
| FILTERS |
| Part No. |
Filters |
Price |
| FLTR |
Aluminum Mesh Filter 1/4' Internal-mount • Set of 2 • (size): Specify size in inches |
$3.74/per in. |
|
|
|
HEATED PRODUCTS SUPPLEMENT
|
|
|
|
|
|
|
NOTE
|
|
|
Before proceeding, refer to the units specific IOM Manual for safety, installation and start information. Verify proper voltage to the product per local and NEC codes. Ensure proper rotation for units with three phase motors.
|
|
|
|
|
|
| Electrically Heated Products |
|
 |
|
|
|
|
Electrically heated products must be mounted on the inside of the building. Electrically heated products come standard with a thermostat (provided and shipped loose, unless ordered as factory pre-mounted) and is to be field installed. |
|
|
Note: 1. Electrically heated Low Profile units come with internally mounted controls and available with optional 24 volt or 240 volt thermostat. |
|
|
2. Electrically heated Standard, High Velocity and Extra Power units include a motor control panel mounted on the right-hand side of the unit, as standard, and a remote 24 volt thermostat with On/Off switch with terminals provided. |
|
|
|
FIG. 1 |
|
3. Electrically heated Wind Stopping and WindGuard units include an electric heater control panel mounted on the right hand side, as standard (FIG. 1). Optional motor/ unit control panel available, which includes a remote 24 volt thermostat with On/Off switch with terminals provided. |
|
|
|
|
|
|
 |
|
|
|
|
The thermostat should be mounted as close to the products discharge air flow as possible in order to best sense the discharged air temperature around the door opening. Connect proper voltage to the product per local and NEC codes. (FIG. 2) |
|
|
|
|
|
Thermal overload protection is built into the heater coil assembly/assemblies. In the event of an overload condition, electrical power will be disconnected from the heater coil. Upon diagnosing the problem, electrical power can be re- instated to the heater coil(s) by manually resetting the thermal overload lever(s) or buttons(s) located in the unit or panel. |
|
|
|
FIG. 2 |
|
|
|
|
|
|
|
|
To operate multiple units mounted side by side, utilizing a single door switch and single thermostat, a master/slave configuration is required. (FIG. 2) |
|
|
|
|
|
LOW PROFILE (LPV) VARIABLE SPEED AND LOW PROFILE (LPN) NSF COMMERCIAL SERIES
|
|
|
Installation, Operation and Maintenance Manual
|
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with these instructions could result in personal injury and/or property damage. Retain these instructions for future reference. |
|
|
|
|
|
|
|
| OVERVIEW |
|
|
 |
|
|
|
|
|
|
|
|
Our Air Curtains are designed to cover door openings, providing both temperature control/environmental separation and flying insect control, when the buildings doors are opened. Typical installation heights are: LoPro Series; LPV (Variable Speed) models (Environmental up to 8), LPN (NSF for Customer Entrances) models |
|
|
|
|
|
(Flying Insect Control up to 7) and LPN-F (NSF for Counter Top/Pass Through Windows) models (Flying Insect Control up to 4 from Counter Top) All NSF Certified Models (ETL) should be mounted at the Flying Insect Control heights referenced above. The units are typically wall mounted horizontally above the door opening. They can also be suspended from the ceiling. The units are ETL Listed, Canada and US, for either an inside or outside mount and ETL Sanitation Certified. Heated units must be mounted on the inside or the protected side of the opening. The motors used in all LoPro Series are 1/6HP.
|
|
|
|
|
|
|
|
|
|
|
WARNING
|
|
To reduce the risk of fire, electric shock or injury to persons, observe the following. |
|
A. Always disconnect, lock and tag power source before installing or servicing product. |
|
B. Installation work or electrical wiring must be done by qualified person(s) in accordance with all ap- plicable codes and standards, including fire-rated construction. |
The LoPro Series come standard with a stamped air intake screen(s). The LPV models can be configured with an aluminum mesh filter(s) as an option. The LPN models 25", 28" and 30" and all LPN-F models come standard with an aluminum mesh air intake filter(s) in conjunction with the punched air intake screen(s). |
|
C. The combustion airflow needed for safe operation of fuel burning equipment in the area may be affected by the products operation. Follow the heating equipment manufacturers guideline and safety standards, such as those published by the National Fire Protection Agency (NFPA), the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities. |
|
|
|
| GENERAL SAFETY INFORMATION |
|
|
Use this product only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Only qualified personnel should install this product. Installing personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Improper installation can result in electric shock, possible injury due to coming in contact with moving parts, as well as other potential hazards. |
|
|
|
|
D.When cutting or drilling into a wall or ceiling, be careful not to damage electrical wiring and other hidden utilities. |
|
|
|
|
|
|
|
|
|
WARNING
|
|
|
|
Precaution should be taken in explosive atmospheres. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: If the holes provided on the bottom of the unit and the bottom of the wall mounting plate do not align, remove the unit and re-install. The holes on the bottom channel of the wall mounted plate must be on the bottom. |
|
WARNING
|
|
|
When servicing the product, motor may be hot enough to cause pain or injury. Allow motor to cool before servicing. |
|
|
|
|
|
| RECEIVING AND INSPECTION |
|
|
|
|
|
|
|
|
|
|
 |
|
|
Upon receiving the product, check to make sure all items are accounted for by referencing the Bill of Lading to ensure all items were received. Inspect each carton for shipping damage before accepting delivery. Notify the freight carrier if any damage is noticed. The carrier will make notification on the delivery receipt acknowledging any damage to the product. All damage should be noted on all copies of the Bill of Lading which is countersigned by the delivering carrier. A Carrier Inspection Report should be filled out by the carrier upon arrival and a report given to the Traffic Department. If damaged upon arrival, file a claim immediately with the carrier. Any physical damage to the unit after acceptance is not our responsibility. |
|
|
|
|
|
|
|
| UNPACKING |
|
|
|
|
|
|
|
|
|
|
Verify that all parts, components and accessories, and the correct quantities of each have been received. If any items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved. |
|
FIG. 1 |
|
|
|
|
|
 |
|
|
|
|
|
|
|
| INSTALLATION |
|
|
|
|
|
Typical Mounting Wall or Ceiling Mounted Horizontally Above the Door Opening
|
|
|
|
|
1. Remove the air intake grille(s) and/or air intake filter(s) from the product and set aside. Gently remove all packaging materials, hardware and all other accessories from interior of unit prior to operating. Severe unit damage will occur if these items are not removed prior to operation. |
|
|
|
|
2. Lay unit on its top with directional vanes pointing up and remove the Tek Screws from the wall mounting plate, just behind the discharge nozzle, and remove the mounting plate from the unit. (FIG. 1) Measure the mounting plate and center it over the opening. The air curtain shall be equal to or greater than the width of the opening. |
|
|
|
|
|
|
|
FIG. 2 |
|
|
|
|
|
|
|
5. Mount the product such that the discharge is 1" above the opening and all obstacles. (FIG. 3) |
|
|
|
Note: If the product is installed higher than the recommended 1" above the opening, then it must be moved 3/8" away from the wall for every 1" that it is moved up. Any void between the wall and the product must be sealed, by others, to optimize performance. |
|
3. Install the mounting plate(s) above the opening. Multiple pre-punched 7/16" mounting holes are provided for your convenience. These holes must be utilized to secure the product to the wall. All hardware is field provided by others. |
|
|
|
|
|
|
|
|
|
6. Use four (4) threaded rods for overhead installation or four (4) threaded bolts for wall installation. All hardware is field provided by others. (FIG. 3) |
|
4. Align the tabs on the rear of the unit with the slots provided on the wall mounting plate (FIG. 2). The bottom flange on the unit must also drop in the bottom channel of the wall mounting plate. Replace the Tek Screws to secure the unit in place. |
|
|
|
|
|
|
|
|
|
|
NOTE
|
|
 |
|
For accessory installation, reference Accessory Installation Supplement. For heated products, reference Heated Products Supplement. |
|
|
|
|
|
START-UP
|
|
This product has been assembled and tested at the factory prior to shipping. The following procedures should be performed to assure its performance. Before continuing with the start-up, it is important to recognize the safety controls furnished with the unit. |
|
|
|
|
WARNING
|
|
Prevent hazard of electrical shock. More than one disconnect switch may be required to de-energize this product. |
|
|
|
|
WARNING
|
|
|
FIG. 3 |
|
|
|
|
The following items must all be completed by a qualified installer and checked off when completed |
|
|
|
|
|
7. If applicable, optional Adjustable Mounting Brackets, Side Extension Plates and Extended Wall Mounted Brackets are also available for installations over a Vertical Lift or Drum Roll-up type door. (Reference Accessory Installation Supplement) 8. If applicable, for tandem installation or products mounted side by side, allow no more than 6" between the two products. For overhead installation using threaded rods, the products may require a beam, by others, to span the full distance of the mounting length. (Reference Accessory Installation Supplement) 9. All wires must be connected internal of the unit and some knockouts are provided. However, it may be necessary to create your own knockout, as required. 10. The unit must be wired per NEC and local codes. |
|
A. Re-check that the product has been installed properly and is level and secure. B. Check all terminal screws are tight and field wiring is connected in accordance to National Electrical Code and wired per the enclosed wiring diagram. For electric heated models, ensure that the coils are secured and not touching each other on any metal surface. C. Verify proper voltage prior to powering the product. (See product label for reference). D. Check all field wired components "if supplied" are wired correctly. E. Check that the inlet air supply and the discharge air supply are free of obstructions. F. Check that all air filter(s) and/or air intake grille(s) are in place and installed properly, as originally shipped. G. Verify voltage to the product once more and turn power on. H. Regardless of whether the product is mounted on the inside or outside of the door opening, set the air directional vanes in the discharge nozzle slightly outward to approximately 10-15° towards the outside, or the wind load. (FIG. 5). |
|
|
|
|
|
| Electrical Field Wiring |
|
The unit and any optional accessories must be wired with the proper voltage to the junction box per the wiring diagram. (FIG. 4, unheated products only) |
|
|
|
|
|
 |
|
|
|
|
 |
|
|
FIG. 5 |
|
|
|
|
I. For products with control panels, turn the HOA (Hand-On-Auto) selector switch to "On" position and open the door to energize the product. For products without a control panel or an On/Off switch, open the door to energize the product. |
|
|
FIG. 4 |
|
|
|
|
|
| MAINTENANCE |
J. If heated products are installed, reference Heated Products Supplement. K. For three phase units, verify direction of rotation of blower wheels (note direction arrows on the blower wheel housing). Correct if needed by changing polarity of three phase power. L. VERY IMPORTANT Using a clamp meter, measure the amperage to each motor and ensure that they do not exceed the amperage listed on the product label. |
|
|
WARNING
|
|
To reduce the risk of fire, electrical shock or injury to persons, observe the following: A. Maintenance is to be performed only by qualified personnel who are familiar with local codes and regulations and are experienced with this type of product. B. Before servicing or cleaning the product switch power off at service panel and lock service panel to prevent power from being switched "ON" accidentally. |
|
|
M. If applicable, adjust the air intake grille(s) such that the output air stream reaches the floor. For tem- perature control and environmental separation applications, the air stream should reach the floor with sufficient strength to create an air seal around the door opening without creating turbulent mixing of the inside and outside air. For flying insect control applications, the air stream should reach the floor with maximum strength. If after proper installation and adjustment, the product appears to be producing too little or too much air for the application, contact the manufacturer. |
|
|
Routine maintenance is required to keep this product operating at its peak performance and efficiency. Over time, the housing, air intake grille, air intake filter, blower wheels and motor(s) will accumulate a build up of dust, debris and other residue. It is imperative to keep these components clean. Failure to do so will not only lower operational efficiency and performance, but also reduce the useful life of the product. The time between cleanings depends on the application, location and daily hours of use. On average, under normal use conditions, the product should require a thorough cleaning once every six (6) months. |
|
|
|
|
|
|
| To clean the product, perform the following: |
4. Thoroughly clean the air intake grille(s)/filter(s). 5. Thoroughly wipe down the motor, blower wheels and blower wheel housings. Be careful not to spray the motor with a water hose. 6. The motor(s) require no additional lubrication. They are permanently lubricated and feature double sealed ball bearings. 7. To re-install the product, reverse the procedures above. 8. Reconnect the power source to the product. 9. If you have any questions regarding the maintenance of the product, contact the manufacturer. |
1. Verify the product has been disconnected from the power source. 2. Use a damp cloth and either a warm mild soapy water solution or bio-degradable degreaser, to wipe down the exterior components of the housing. 3. To access the interior of the product, remove the air intake grille(s) and/or air intake filter(s). This is accomplished by removing the screws on the face of the air intake grille(s)/filter(s). |
|
|
|
Commercial Air Curtains, Air Curtain, Air Curtain Door, Air Curtain Heater, Air Curtains, Air Doors, Door Air Curtains, Heat Curtains, Mars Air Curtain, Mars Air Door, Warm Air Curtains, and Insect Barrier from your source for material handling equipment.
|
|