ELECTRIC HEATED AIR CURTAINS
|
|
| FREE FREIGHT |
| FOR ALL AIR CURTAINS SHIPPED TO LOCATIONS WITHIN THE 48 CONTIGUOUS UNITED STATES |
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
Q
|
The first question is, do I really need a heated air curtain? |
| A |
The answer is maybe not. Air doors effectively create an efficient insulation barrier between two environments. It's approximately 80% - 90% efficient. It does so by creating a stiff blast of air blowing down from the unit towards the floor. This blast of air create an invisible barrier separating the two environments. If you have people working near or walking through this moving air, they may feel a breeze. This could cause a wind chill effect, similar to the cooling effects of a blowing fan during the summer. Adding a heated air curtain unit will minimize this effect and make for a comfortable and more productive work place for your employees and customers. Should your facility be located in a cold weather environment creating significant temperature differences between the outside versus the inside temperature, a heated unit will signi- ficantly improve the work environment comfort level and help maintain consistent temperature control. In addition, it will reduce overall utility and maintenance costs by providing a more constant inside temperature. |
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TYPICAL USES |
|
|
|
|
Easily mounted over entrance ways of warehouse doors up to 16 feet high, the air curtains direct an invisible stream of stratified heated air downward. In addition to adding to employee and customer comfort during cold weather they provide important energy savings in three ways: |
|
|
|
|
|
|
|
|
|
|
|
|
|
1. In cold weather they reduce the load on heating systems. By drawing warm air down to floor level where it is needed, our air curtains utilize the 50% of wasted heated air trapped under ceilings. Stratified air is mixed and circulated with building heat and heat given off by lights and machinery, etc. |
|
|
|
|
|
|
|
|
|
|
|
ENERGY |
|
|
Our air curtains conserve energy and improve comfort by limiting the escape of internal heat, reducing cold drafts and providing a welcoming down flow curtain of warm air at entrance ways in industrial plants and store buildings. The resulting mixture of warmed air disperses gently in all directions at floor level to give uniform temperature over a wide area from floor to ceiling with only a few degrees difference. |
|
|
|
|
|
|
|
2. The high velocity curtain of air deflects winds and reduces excessive heat loss through open doorways. |
|
|
|
|
|
|
|
|
|
3. During warm weather they can direct a stream of air downward to help keep dust, dirt, insects and fumes from entering through open doorways. If air conditioning exists in the building during warm weather, the air curtains can be used to prevent loss of conditioned air as well. |
|
|
|
|
|
|
|
|
|
CONVENIENCE |
|
Our air curtains allow personnel and cargo to pass freely from one area to another while maintaining desired temperatures. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
An added safety feature is the free flow of traffic with an unobstructed view through the opening, eliminating doorway accidents. |
|
|
|
|
|
|
|
Our air curtains create an invisible barrier of high velocity air to stop cold or warm air infiltrating plant facilities and work areas. |
Stop entry of cold or warm air when doors are open. |
|
Prevent the possibility of accidents with unobstructed view of passageways. |
|
IMPORTANT: MUST BE INSTALLED ON WARM SIDE OF DOORWAY OPENING WHEN USED FOR TEMPERATURE CONTROL |
Eliminate need for expensive plastic stripping, flapper doors, or canvas curtains. |
|
Cold weather can be further deterred at door opening if space heater in plant is directed toward intake of the air curtain. |
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
| SPECIFICATIONS AND FEATURES |
|
|
|
|
|
|
|
| FOR ARCHITECTS AND ENGINEERS |
|
EASY INSTALLATION |
Our air curtains shall have a self-contained one piece housing, fire retardant and corrosion proof, incorporated with a double extended shaft motor, direct drive double width and double inlet squirrel cage blower wheels and fan housings. |
Our air curtains are bolted to wall with four fasteners and connected to electric power source. |
AIR VELOCITY CONTROL FOR VARIABLE AIR SPEED |
Shall have wedge shaped discharge nozzle containing adjustable air deflectors with 40% sweep front to back. |
|
Adjustable louver damper controls are provided in order to adjust rate of air flow. |
Housing shall be sufficient strength for fastening to wall on both ends without any intermediate support. |
|
When used over a doorway to retain warm or cold temperature, proper velocity adjustment is imperative for maximum efficiency. Velocity Control can reduce air velocity up to 60% with louvers in totally closed position. |
| HEAVY DUTY ELECTRIC MOTOR |
|
Continuous duty type motor with double sealed lifetime pre-lubricated stainless steel ball bearings, resilient mounted and protected by an automatic thermal over- load switch. Underwriters Laboratories Listed and Canadian Standards Association Certified. Explosion proof motors available. |
|
|
AIR DIRECTIONAL CONTROL |
|
Adjustable vanes at outlet nozzle for directing air to compensate for possible draft conditions through doorways. |
|
|
|
|
|
|
|
| FIRE RETARDANT AND CORROSION PROOF |
|
|
|
|
|
Steel models are of 18 gauge paint lock metal and double protected with gray, baked, rust preventative electrostatic polyurethane powder coating. |
|
|
|
|
How Air Curtain Works!
|
|
| NOISE LEVEL |
|
|
|
|
|
|
|
 |
|
Our air curtains operate under a low noise level in the interest and comfort of personnel working in the immediate vicinity. |
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
SELECTION TABLE
|
|
Model No.
|
Width of Door
|
Door Height
|
FLA (Ampacity) Single Phase
|
Sound dBA
|
Weight (lbs)
|
|
115V
|
208V/230V
|
|
STD236
|
36"
|
8' - 10'
|
5.1
|
2.5 / 2.5
|
66
|
50
|
|
STD242
|
42"
|
8' - 10'
|
5.1
|
2.5 / 2.5
|
66
|
55
|
|
STD248
|
48"
|
8' - 10'
|
5.1
|
2.5 / 2.5
|
66
|
60
|
|
STD264-2
|
64"
|
8' - 10'
|
10.2
|
5.0 / 5.0
|
68
|
95
|
|
STD272-2
|
72"
|
8' - 10'
|
10.2
|
5.0 / 5.0
|
68
|
100
|
|
STD278-2
|
78"
|
8' - 10'
|
10.2
|
5.0 / 5.0
|
68
|
110
|
|
STD284-2
|
84"
|
8' - 10'
|
10.2
|
5.0 / 5.0
|
68
|
115
|
|
STD296-2
|
96"
|
8' - 10'
|
10.2
|
5.0 / 5.0
|
68
|
125
|
|
STD296-3
|
96"
|
8' - 10'
|
15.3
|
7.5 / 7.5
|
71
|
170
|
|
STD2108-2
|
108"
|
8' - 10'
|
10.2
|
5.0 / 5.0
|
71
|
130
|
|
STD2108-3
|
108"
|
8' - 10'
|
15.3
|
7.5 / 7.5
|
71
|
175
|
|
STD2120-3
|
120"
|
8' - 10'
|
15.3
|
7.5 / 7.5
|
71
|
185
|
|
STD2144-3
|
144"
|
8' - 10'
|
15.3
|
7.5 / 7.5
|
71
|
205
|
|
STD2144-4
|
144"
|
8' - 10'
|
20.4
|
10.0 / 10.0
|
73
|
215
|
|
HV242
|
42"
|
10' - 12'
|
3.3 / 3.2
|
1.6
|
70
|
90
|
|
HV248
|
48"
|
10' - 12'
|
3.3 / 3.2
|
1.6
|
70
|
95
|
|
HV260
|
60"
|
10' - 12'
|
3.3 / 3.2
|
1.6
|
70
|
105
|
|
HV272-2
|
72"
|
10' - 12'
|
6.6 / 6.4
|
3.2
|
73
|
165
|
|
HV284-2
|
84"
|
10' - 12'
|
6.6 / 6.4
|
3.2
|
73
|
180
|
|
HV296-2
|
96"
|
10' - 12'
|
6.6 / 6.4
|
3.2
|
73
|
190
|
|
HV296-3
|
96"
|
10' - 12'
|
9.9 / 9.6
|
4.8
|
75
|
240
|
|
HV2108-2
|
108"
|
10' - 12'
|
6.6 / 6.4
|
3.2
|
73
|
200
|
|
HV2108-3
|
108"
|
10' - 12'
|
9.9 / 9.6
|
4.8
|
75
|
255
|
|
HV2120-2
|
120"
|
10' - 12'
|
6.6 / 6.4
|
3.2
|
73
|
215
|
|
HV2120-3
|
120"
|
10' - 12'
|
9.9 / 9.6
|
4.8
|
75
|
270
|
|
HV2144-3
|
144"
|
10' - 12'
|
9.9 / 9.6
|
4.8
|
75
|
295
|
|
HV2144-4
|
144"
|
10' - 12'
|
13.2 / 12.8
|
6.4
|
75
|
375
|
|
|
 |
|
|
|
 |
|
MODEL NUMBER CONFIGURATION |
|
 |
|
|
Click the button of the item you wish to purchase. Contact us for special lengths
|
|
|
|
|
| Standard Features: |
½ hp direct-drive motor Sleek metal design Easy install Motor fan assembly 18-month warranty |
Made in USA |
Standard Color: |
|
|
 |
|
|
Protection Environmental: 10 Flying-insects: 8 |
|
|
|
|
|
|
PRICING AND SPECIFICATIONS (ELECTRIC HEATED MODELS)
|
Full freight allowed. Prices included delivery to any destination within the Continental United States or to Port of Embarkation for Overseas shipments. |
|
|
IMMEDIATE FREE DELIVERY MADE WITH PRIDE IN THE USA
|
|
|
ELECTRIC HEATED STANDARD SERIES PRICES
|
|
Models
|
Voltage
|
kW
|
Air Volume (max.)
|
Length
|
Height
|
Depth
|
Full Load Draw
|
Wgt. (lbs)
|
Avg. Velocity
|
# of motors
|
PRICE
|
|
|
208/1/60
|
6kW
|
1379cfm
|
36"
|
10 5/8"
|
17 3/8"
|
31amps
|
90
|
2206fpm
|
1
|
$3,100.90
|
|
|
230/1/60
|
6kW
|
1379cfm
|
36"
|
10 5/8"
|
17 3/8"
|
29amps
|
90
|
2206fpm
|
1
|
$3,100.90
|
|
|
208/3/60
|
12kW
|
1379cfm
|
36"
|
10 5/8"
|
17 3/8"
|
36amps
|
90
|
2206fpm
|
1
|
$3,100.90
|
|
|
230/3/60
|
12kW
|
1379cfm
|
36"
|
10 5/8"
|
17 3/8"
|
33amps
|
90
|
2206fpm
|
1
|
$3,100.90
|
|
|
460/3/60
|
12kW
|
1379cfm
|
36"
|
10 5/8"
|
17 3/8"
|
16amps
|
90
|
2206fpm
|
1
|
$3,100.90
|
|
|
208/1/60
|
6kW
|
1418cfm
|
42"
|
10 5/8"
|
17 3/8"
|
31amps
|
95
|
1945fpm
|
1
|
$3,212.00
|
|
|
230/1/60
|
6kW
|
1418cfm
|
42"
|
10 5/8"
|
17 3/8"
|
29amps
|
95
|
1945fpm
|
1
|
$3,212.00
|
|
|
208/3/60
|
12kW
|
1418cfm
|
42"
|
10 5/8"
|
17 3/8"
|
36amps
|
95
|
1945fpm
|
1
|
$3,212.00
|
|
|
230/3/60
|
12kW
|
1418cfm
|
42"
|
10 5/8"
|
17 3/8"
|
33amps
|
95
|
1945fpm
|
1
|
$3,212.00
|
|
|
460/3/60
|
12kW
|
1418cfm
|
42"
|
10 5/8"
|
17 3/8"
|
16amps
|
95
|
1945fpm
|
1
|
$3,212.00
|
|
|
208/1/60
|
6kW
|
1442cfm
|
48"
|
10 5/8"
|
17 3/8"
|
31amps
|
100
|
1730fpm
|
1
|
$3,252.70
|
|
|
230/1/60
|
6kW
|
1442cfm
|
48"
|
10 5/8"
|
17 3/8"
|
29amps
|
100
|
1730fpm
|
1
|
$3,252.70
|
|
|
208/3/60
|
12kW
|
1442cfm
|
48"
|
10 5/8"
|
17 3/8"
|
36amps
|
100
|
1730fpm
|
1
|
$3,252.70
|
|
|
230/3/60
|
12kW
|
1442cfm
|
48"
|
10 5/8"
|
17 3/8"
|
33amps
|
100
|
1730fpm
|
1
|
$3,252.70
|
|
|
460/3/60
|
12kW
|
1442cfm
|
48"
|
10 5/8"
|
17 3/8"
|
16amps
|
100
|
1730fpm
|
1
|
$3,252.70
|
|
|
208/1/60
|
6kW
|
2700cfm
|
60"
|
10 5/8"
|
17 3/8"
|
63amps
|
115
|
2592fpm
|
1
|
$5,221.70
|
|
|
230/1/60
|
6kW
|
2700cfm
|
60"
|
10 5/8"
|
17 3/8"
|
57amps
|
115
|
2592fpm
|
1
|
$5,221.70
|
|
|
208/3/60
|
12kW
|
2700cfm
|
60"
|
10 5/8"
|
17 3/8"
|
72amps
|
115
|
2592fpm
|
1
|
$5,221.70
|
|
|
230/3/60
|
12kW
|
2700cfm
|
60"
|
10 5/8"
|
17 3/8"
|
65amps
|
115
|
2592fpm
|
1
|
$5,221.70
|
|
|
460/3/60
|
12kW
|
2700cfm
|
60"
|
10 5/8"
|
17 3/8"
|
31amps
|
115
|
2592fpm
|
1
|
$5,221.70
|
|
|
208/1/60
|
12kW
|
2758cfm
|
72"
|
10 5/8"
|
17 3/8"
|
63amps
|
180
|
2206fpm
|
2
|
$5,782.70
|
|
|
230/1/60
|
12kW
|
2758cfm
|
72"
|
10 5/8"
|
17 3/8"
|
57amps
|
180
|
2206fpm
|
2
|
$5,782.70
|
|
|
208/3/60
|
24kW
|
2758cfm
|
72"
|
10 5/8"
|
17 3/8"
|
72amps
|
180
|
2206fpm
|
2
|
$5,782.70
|
|
|
230/3/60
|
24kW
|
2758cfm
|
72"
|
10 5/8"
|
17 3/8"
|
65amps
|
180
|
2206fpm
|
2
|
$5,782.70
|
|
|
460/3/60
|
24kW
|
2758cfm
|
72"
|
10 5/8"
|
17 3/8"
|
31amps
|
180
|
2206fpm
|
2
|
$5,782.70
|
|
|
208/1/60
|
12kW
|
2836cfm
|
84"
|
10 5/8"
|
17 3/8"
|
63amps
|
190
|
1945fpm
|
2
|
$6,011.50
|
|
|
230/1/60
|
12kW
|
2836cfm
|
84"
|
10 5/8"
|
17 3/8"
|
57amps
|
190
|
1945fpm
|
2
|
$6,011.50
|
|
|
208/3/60
|
24kW
|
2836cfm
|
84"
|
10 5/8"
|
17 3/8"
|
72amps
|
190
|
1945fpm
|
2
|
$6,011.50
|
|
|
230/3/60
|
24kW
|
2836cfm
|
84"
|
10 5/8"
|
17 3/8"
|
65amps
|
190
|
1945fpm
|
2
|
$6,011.50
|
|
|
460/3/60
|
24kW
|
2836cfm
|
84"
|
10 5/8"
|
17 3/8"
|
31amps
|
190
|
1945fpm
|
2
|
$6,011.50
|
|
|
208/1/60
|
12kW
|
2884cfm
|
96"
|
10 5/8"
|
17 3/8"
|
63amps
|
225
|
1730fpm
|
2
|
$6,142.40
|
|
|
230/1/60
|
12kW
|
2884cfm
|
96"
|
10 5/8"
|
17 3/8"
|
57amps
|
225
|
1730fpm
|
2
|
$6,142.40
|
|
|
208/3/60
|
24kW
|
2884cfm
|
96"
|
10 5/8"
|
17 3/8"
|
72amps
|
225
|
1730fpm
|
2
|
$6,142.40
|
|
|
230/3/60
|
24kW
|
2884cfm
|
96"
|
10 5/8"
|
17 3/8"
|
65amps
|
225
|
1730fpm
|
2
|
$6,142.40
|
|
|
460/3/60
|
24kW
|
2884cfm
|
96"
|
10 5/8"
|
17 3/8"
|
31amps
|
225
|
1730fpm
|
2
|
$6,142.40
|
|
|
460/3/60
|
36kW
|
4137cfm
|
108"
|
10 5/8"
|
17 3/8"
|
47amps
|
270
|
2206fpm
|
3
|
$7,822.10
|
|
|
460/3/60
|
36kW
|
4341cfm
|
120"
|
10 5/8"
|
17 3/8"
|
47amps
|
280
|
2084fpm
|
3
|
$7,955.20
|
|
|
460/3/60
|
36kW
|
4326cfm
|
144"
|
10 5/8"
|
17 3/8"
|
47amps
|
330
|
1730fpm
|
3
|
$8,083.90
|
|
|
 |
|
OB
|
|
TS
|
|
PW
|
|
|
|
|
|
|
|
|
| Optional Color Available - Std. Production Color is Obsidian Black (matte) See add-on prices below. |
|
|
|
|
|
|
|
|
Prices for Colors That are not Standard for the Series (add these prices to price of electric heated standard air curtain)
|
| Length of Unit |
25" |
36" |
42" |
48" |
60" |
64" |
72" |
84" |
96" |
108" |
120" |
144" |
| TS |
|
|
|
|
|
|
|
|
|
|
|
|
| PW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Full freight allowed. Prices included delivery to any destination within the Continental United States or to Port of Embarkation for Overseas shipments. |
|
|
IMMEDIATE FREE DELIVERY MADE WITH PRIDE IN THE USA
|
|
|
|
|
|
| Standard Features: |
Standard Color: |
|
1 hp direct-drive motor Sleek metal design Easy install Motor fan assembly 18-month warranty Made in USA |
|
Protection Environmental: 12 Flying-insects: 10 |
 |
|
|
|
|
|
|
|
|
|
|
MODEL NUMBER CONFIGURATION |
 |
|
|
|
|
 |
|
|
Click the button of the item you wish to purchase. Contact us for special lengths
|
ELECTRIC HEATED HIGH VELOCITY MODELS PRICES
|
|
Models
|
Voltage
|
kW
|
Air Volume (max.)
|
Length
|
Height
|
Depth
|
Full Load Draw
|
Wgt. (lbs)
|
Avg. Velocity
|
# of motors
|
PRICE
|
|
|
208/1/60
|
6kW
|
2447cfm
|
48"
|
14"
|
21 3/8"
|
32amps
|
145
|
2447fpm
|
1
|
$3,983.10
|
|
|
230/1/60
|
6kW
|
2447cfm
|
48"
|
14"
|
21 3/8"
|
29amps
|
145
|
2447fpm
|
1
|
$3,983.10
|
|
|
208/3/60
|
12kW
|
2447cfm
|
48"
|
14"
|
21 3/8"
|
37amps
|
145
|
2447fpm
|
1
|
$3,983.10
|
|
|
230/3/60
|
12kW
|
2447cfm
|
48"
|
14"
|
21 3/8"
|
33amps
|
145
|
2447fpm
|
1
|
$3,983.10
|
|
|
460/3/60
|
12kW
|
2447cfm
|
48"
|
14"
|
21 3/8"
|
17amps
|
145
|
2447fpm
|
1
|
$3,983.10
|
|
|
208/1/60
|
6kW
|
2760cfm
|
48"
|
14"
|
21 3/8"
|
32amps
|
155
|
2208fpm
|
1
|
$4,066.70
|
|
|
230/1/60
|
6kW
|
2760cfm
|
48"
|
14"
|
21 3/8"
|
29amps
|
155
|
2208fpm
|
1
|
$4,066.70
|
|
|
208/3/60
|
12kW
|
2760cfm
|
60"
|
14"
|
21 3/8"
|
37amps
|
155
|
2208fpm
|
1
|
$4,066.70
|
|
|
230/3/60
|
12kW
|
2760cfm
|
60"
|
14"
|
21 3/8"
|
33amps
|
155
|
2208fpm
|
1
|
$4,066.70
|
|
|
460/3/60
|
12kW
|
2760cfm
|
60"
|
14"
|
21 3/8"
|
17amps
|
155
|
2208fpm
|
1
|
$4,066.70
|
|
|
208/1/60
|
12kW
|
3584cfm
|
48"
|
14"
|
21 3/8"
|
64amps
|
315
|
2389fpm
|
2
|
$7,566.90
|
|
|
230/1/60
|
12kW
|
3584cfm
|
48"
|
14"
|
21 3/8"
|
59amps
|
315
|
2389fpm
|
2
|
$7,566.90
|
|
|
208/3/60
|
24kW
|
3584cfm
|
72"
|
14"
|
21 3/8"
|
73amps
|
315
|
2389fpm
|
2
|
$7,566.90
|
|
|
230/3/60
|
24kW
|
3584cfm
|
72"
|
14"
|
21 3/8"
|
67amps
|
315
|
2389fpm
|
2
|
$7,566.90
|
|
|
460/3/60
|
24kW
|
3584cfm
|
72"
|
14"
|
21 3/8"
|
33amps
|
315
|
2389fpm
|
2
|
$7,566.90
|
|
|
208/1/60
|
12kW
|
4644cfm
|
48"
|
14"
|
21 3/8"
|
64amps
|
335
|
2654fpm
|
2
|
$7,682.40
|
|
|
230/1/60
|
12kW
|
4644cfm
|
48"
|
14"
|
21 3/8"
|
59amps
|
335
|
2654fpm
|
2
|
$7,682.40
|
|
|
208/3/60
|
24kW
|
4644cfm
|
84"
|
14"
|
21 3/8"
|
73amps
|
335
|
2654fpm
|
2
|
$7,682.40
|
|
|
230/3/60
|
24kW
|
4644cfm
|
84"
|
14"
|
21 3/8"
|
67amps
|
335
|
2654fpm
|
2
|
$7,682.40
|
|
|
460/3/60
|
24kW
|
4644cfm
|
84"
|
14"
|
21 3/8"
|
33amps
|
335
|
2654fpm
|
2
|
$7,682.40
|
|
|
208/1/60
|
12kW
|
4894cfm
|
48"
|
14"
|
21 3/8"
|
64amps
|
340
|
2447fpm
|
2
|
$7,775.90
|
|
|
230/1/60
|
12kW
|
4894cfm
|
48"
|
14"
|
21 3/8"
|
59amps
|
340
|
2447fpm
|
2
|
$7,775.90
|
|
|
208/3/60
|
24kW
|
4894cfm
|
96"
|
14"
|
21 3/8"
|
73amps
|
340
|
2447fpm
|
2
|
$7,775.90
|
|
|
230/3/60
|
24kW
|
4894cfm
|
96"
|
14"
|
21 3/8"
|
67amps
|
340
|
2447fpm
|
2
|
$7,775.90
|
|
|
460/3/60
|
24kW
|
4894cfm
|
96"
|
14"
|
21 3/8"
|
33amps
|
340
|
2447fpm
|
2
|
$7,775.90
|
|
|
460/3/60
|
36kW
|
5376cfm
|
108"
|
14"
|
21 3/8"
|
50amps
|
425
|
2389fpm
|
3
|
$10,365.30
|
|
|
208/1/60
|
12kW
|
5519cfm
|
48"
|
14"
|
21 3/8"
|
64amps
|
365
|
2208fpm
|
2
|
$7,945.30
|
|
|
230/1/60
|
12kW
|
5519cfm
|
48"
|
14"
|
21 3/8"
|
59amps
|
365
|
2208fpm
|
2
|
$7,945.30
|
|
|
208/3/60
|
24kW
|
5519cfm
|
120"
|
14"
|
21 3/8"
|
73amps
|
365
|
2208fpm
|
2
|
$7,945.30
|
|
|
230/3/60
|
24kW
|
5519cfm
|
120"
|
14"
|
21 3/8"
|
67amps
|
365
|
2208fpm
|
2
|
$7,945.30
|
|
|
460/3/60
|
24kW
|
5519cfm
|
120"
|
14"
|
21 3/8"
|
33amps
|
365
|
2208fpm
|
2
|
$7,945.30
|
|
|
460/3/60
|
36kW
|
6693cfm
|
120"
|
14"
|
21 3/8"
|
50amps
|
440
|
2678fpm
|
3
|
$10,480.80
|
|
|
460/3/60
|
36kW
|
7341cfm
|
144"
|
14"
|
21 3/8"
|
50amps
|
465
|
2447fpm
|
3
|
$10,681.00
|
|
|
 |
|
OB
|
|
TS
|
|
PW
|
|
|
|
|
|
|
|
|
|
| Optional Color Available - Std. Production Color is Titanium Silver See add-on prices below. |
|
|
|
|
|
|
|
|
|
|
|
Prices for Colors That are not Standard for the Series (add these prices to price of standard air curtain)
|
| Length of Unit |
25" |
36" |
42" |
48" |
60" |
64" |
72" |
84" |
96" |
108" |
120" |
144" |
|
OB
|
|
|
|
|
|
|
|
|
|
|
|
|
| PW |
|
|
|
|
|
|
|
|
|
|
|
|
|
Click the button of the item you wish to purchase. Contact us for special lengths
|
|
ACCESSORIES - Electric Heated
|
|
| DOOR SWITCHES |
| Automatic on/off control of air curtain as door is opened and closed |
| LINE VOLTAGE |
| Part No. |
Package |
Price |
|
|
Steel Mechanical Universal Surface-Mounted Plunger/Roller Switch |
$168.19 |
| 24-Volt Control |
|
|
Industrial Floor-Mounted Magnetic Reed Switch Only - Floor mounted. Note: Control panel required. |
$392.37
|
|
|
Industrial Surface-Mounted Magnetic Reed Switch Only. Surface-mounted. Note: Control panel required. |
$392.37
|
|
|
| CONTROL PACKAGES |
| Combination packages of door switches, controllers, time delays, and thermostats |
| LINE VOLTAGE |
| Part No. |
Package |
Price |
|
|
Analog Thermostat - Remote-mounted
|
$196.13
|
|
| OPTIONAL CONTROLS - Can be paired with any control package |
|
Part No.
|
Package |
Price
|
|
|
Master/Slave Control with Single Thermostat |
$235.40
|
|
|
MOUNTING BRACKETS
|
| Part No. |
Mounting Bracket |
Price |
Recommended for specific applications · Standard color Titanium Silver · NOTE: Units come standard with predrilled holes on back end for flush mounting |
|
|
5" Flat Side Extension Plates - to clear track on either end - Set of 2 |
$196.13
|
|
|
7" Flat Side Extension Plates - to clear track on either end - Set of 2 |
$196.13
|
|
|
9" Flat Side Extension Plates - to clear track on either end - Set of 2 |
$196.13
|
|
|
2 1/2"-Clearance Adjustable-Angle Mounting Bracket To clear wall obstructions - Set of 2 |
$196.13
|
|
|
4"-Clearance Adjustable-Angle Mounting Bracket To clear wall obstructions - Set of 2 |
$392.37
|
|
|
7"-Clearance Adjustable-Angle Mounting Bracket To clear wall obstructions - Set of 2 |
$392.37
|
|
|
10"-Clearance Adjustable-Angle Mounting Bracket To clear wall obstructions - Set of 2 |
$392.37
|
|
|
10"-Clearance Drum-Roll-Style Extended Wall Mounting Bracket For use over drum-style roll-up doors - Set of 2 |
$470.80
|
|
|
16"-Clearance Drum-Roll-Style Extended Wall Mounting Bracket For use over drum-style roll-up doors - Set of 2 |
$470.80
|
|
|
19"-Clearance Drum-Roll-Style Extended Wall Mounting Bracket For use over drum-style roll-up doors - Set of 2 |
$496.98
|
|
|
23"-Clearance Drum-Roll-Style Extended Wall Mounting Bracket For use over drum-style roll-up doors - Set of 2 |
$601.59
|
|
| FILTERS |
| Part No. |
Filters |
Price |
| FLTR |
HV2 Aluminum Mesh Filter 1/4' Internal-mount - Set of 2 - (size): Specify size in inches |
$3.74/per inch |
|
|
|
|
1/2 HP STANDARD HEATED MODELS DRAWING
|
|
|
|
|
|
|
 |
NOTES: |
|
1. This product is designed to meet the National Electric Code (NEC) and is ETL Listed for the US and Canada and bear the CE Mark. |
|
2. 7/16" mounting holes (4) provided, (2) on each end, 1/2" key hole slots (2) provided, (1) on each end for wall mounting. |
|
3. All units have a self contained one piece cabinet, fire retardant and corrosion proof paint lock metal, double protected with baked on Obsidian Black color rust preventative electrostatic polyurethane powder coating. |
|
4. Cabinet has sufficient strength for suspension from both ends without intermediate support. |
|
5. Control panel is prewired and premounted inside the cabinet. Optional remote mounted available. |
|
6. Unit is to be installed such that air flow is unob- structed. Air discharge nozzle containing adjustable air directional vanes with 40° sweep front to back. |
|
7. Wall mounted 24 volt thermostat with remote"heat/ off/fan" switch shipped loose and field installed. Terminal block provided inside panel. |
|
| 8. Branch circuit protected as per NEC by others. |
|
9. Optional door limit switch is field installed and is to be wired to the control panel. Switch to be mounted such that the air curtain turns on as door begins to open. A time delay is highly re- commended with the optional door limit switch. |
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*NOTE: Intake screen size and number varies with unit length. |
| -2 &-3 designates the number of motors. |
|
|
|
|
|
|
|
|
 |
|
Model No. |
Mounting Centers A |
Length B |
|
STD236-1E
|
35 1/8"
|
36"
|
|
STD242-1E
|
41 1/8"
|
42"
|
|
STD248-1E
|
47 1/8"
|
48"
|
|
STD260-1E
|
59 1/8"
|
60"
|
|
STD260-2E
|
59 1/8"
|
60"
|
|
STD264-2E
|
63 1/8"
|
64"
|
|
STD272-2E
|
71 1/8"
|
72"
|
|
STD278-2E
|
77 1/8"
|
78"
|
|
STD284-2E
|
83 1/8"
|
84"
|
|
STD296-2E
|
95 1/8"
|
96"
|
|
STD296-3E
|
95 1/8"
|
96"
|
|
STD2108-3E
|
107 1/8"
|
108"
|
|
STD2120-3E
|
119 1/8"
|
120"
|
|
STD2144-3E
|
143 1/8"
|
144"
|
|
STD2144-4E
|
143 1/8"
|
144"
|
|
|
|
|
|
TYPICAL INSTALLATION |
|
1. Connect supply voltage from power panel to control panel. (8) 2. Connect wires from motor leads in junction box to terminals in panel per print. 3. Connect wires from door limit switch to terminals in panel per print. 4. Check rotation of motors and switch leads if necesary to correct. |
|
|
|
HIGH VELOCITY AND EXTRA POWER ELECTRIC HEATED MODELS DRAWING
|
|
|
|
|
|
|
 |
NOTES: |
|
1. This product is designed to meet the National Electric Code (NEC) and is ETL Listed for the US and Canada and bear the CE Mark.. |
|
2. 7/16" mounting holes (4) provided, (2) on each end. 1/2" key hole slots (2) provided, (1) on each end for wall mounting. |
|
3. All units have a self contained one piece cabinet, fire retardant and corrosion proof paint lock metal, double protected with baked on Titanium Silver color rust preventative electrostatic polyurethane powder coating. |
|
4. Cabinet has sufficient strength for suspension from both ends without intermediate support. |
|
5. Control panel is prewired and premounted inside the cabinet. Optional remote mounted available. |
|
6. Unit is to be installed such that air flow is unob- structed. Air discharge nozzle containing adjustable air directional vanes with 40° sweep front to back. |
|
7. Wall mounted 24 volt thermostat with remote"heat/ off/fan" switch shipped loose and field installed. Terminal block provided inside panel. |
|
| 8. Branch circuit protected as per NEC by others. |
|
9. Optional door limit switch is field installed and is to be wired to the control panel. Switch to be mounted such that the air curtain turns on as door begins to open. A time delay is highly recommended with the optional microswitch. |
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| -2 &-3 designates the number of motors. |
|
|
*NOTE: Intake screen size and number varies with unit length. |
|
Model No.
|
Mounting Centers A
|
Overall Length B
|
|
HV242-1E
|
41 1/8"
|
42"
|
|
HV248-1E
|
47 1/8"
|
48"
|
|
HV260-1E
|
59 1/8"
|
60"
|
|
HV722-2E
|
71 1/8"
|
72"
|
|
HV284-2E
|
83 1/8"
|
84"
|
|
HV296-2E
|
95 1/8"
|
96"
|
|
HV2108-2E
|
107 1/8"
|
108"
|
|
HV2108-3E
|
107 1/8"
|
108"
|
|
HV2120-2E
|
119 1/8"
|
120"
|
|
HV2120-3E
|
119 1/8"
|
120"
|
|
HV2144-3E
|
143 1/8"
|
144"
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
TYPICAL INSTALLATION |
|
1. Connect supply voltage from power panel to control panel. (9) 2. Connect wires from motor leads in junction box to terminals in panel per print. 3. Connect wires from door limit switch to terminals in panel per print. 4. Check rotation of motors and switch leads if necesary to correct. |
|
|
|
|
|
INSTALLATION INSTRUCTIONS FOR ELECTRIC HEATED HIGH VELOCITY AND EXTRA POWER MODELS
|
|
|
|
|
|
|
|
PRELIMINARY
|
|
TO INSTALL HOUSING AND MOTOR/FAN ASSEMBLY
|
|
|
1. Before removing the unit from the carton, unscrew the plastic nuts and remove the adjustable velocity control louver. 2. Remove the Motor/Fan Assembly from its carton. Industrial models have the motor/fan assembly(s) shipped separately. Be careful not to touch the dynamically balanced wheels or damage the electric heating elements when removing the motor/ fan assembly from the box. 3. Remove the housing from the carton. WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Installation work or electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standard, including fire-rated construction. B. The combustion airflow needed for safe operation of fuel burning equipment in the area may be affected by the unit's operation. Follow the heating equipment manu- facturer's guideline and safety standards, such as those published by the National Fire Protection Association (NFPA), the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities. C. When cutting or drilling into a wall or ceiling, be careful not to damage electrical wiring and other hidden utilities.
|
|
|
1. Measure the housing, and then center it on the wall over the doorway opening. See Table I for the minimum clearance required on the panel side of the unit for access and service. 2. Spot holes through 7/16" mounting holes. (2) on each end of the housing. If necessary, drill extra holes in the back of the housing to align with stud spacing. (See Figure 1) 3. Mount the unit with the discharge nozzle 1" above the door opening. If the unit is mounted higher, move it 3/8" away from the wall for every 1" it is moved up above the door. Any void between wall and unit must be sealed for optimum performance. Threaded rods may be used for overhead installation. 4. Use all four mounting holes when installing the housing. 5. When mounting multiple units side by side, allow no more than 6" between the units. Master/Slave configuration required to allow the units to operate simultaneously. (Single T'stat Control) (see figure 2) 6. Replace Motor/Fan Assembly(s) in the housing and secure with wingnuts. Connect all motor(s) and electric heater(s) connections. 7. Replace the intake louver or inlet screen and fasten with the hex nuts. 8. Connect panel to proper voltage. Check the motor rotation. (See Figure 1)
|
|
|
|
|
|
|
|
|
|
|
|
TABLE 1
|
|
ADJUSTMENTS
|
|
|
Model No. |
Motor HP |
Number of Motors |
Mounting Centers A |
Min. Panel Clearance Req'd (B) |
| HV248-1E |
1 |
1 |
47 1/8" |
17" |
| HV260-1E |
1 |
1 |
59 1/8" |
17" |
| HV272-2E |
1 |
2 |
71 1/8" |
21" |
| HV284-2E |
1 |
2 |
83 1/8" |
21" |
| HV296-2E |
1 |
2 |
95 1/8" |
21" |
| HV2120-2E |
1 |
2 |
119 1/8" |
21" |
| HV2120-3E |
1 |
3 |
119 1/8" |
21" |
| HV2144-3E |
1 |
3 |
143 1/8" |
21" |
|
|
|
|
|
1. Pull air directional vanes in air discharge nozzle to proper position with air flow slated slightly outward around 15°. 2. Set air velocity control louvers so that the air stream just reaches the floor to prevent turbulent mixing of inside and outside air. 3. The unit is to be installed such that the airflow is unobstructed. 4. The thermostat should be mounted such that it senses the room temperature. Do not mount thermostat on a cold wall, below a discharge grill or in direct sunlight. The high limit switches may trip, shutting off the heat, if improperly installed. |
|
|
|
NOTE: MODEL NUMBER DESIGNATES THE LENGTH OF THE UNIT IN INCHES, WHICH IS DENOTED AS "L". ALL DIMENSIONS ARE IN INCHES. |
|
|
|
|
|
|
|
|
|
|
|
CONTROL PANEL INSTALLATION
|
|
A. Connect supply voltage from power panel to control panel. Circuit protection as per NEC by others. B. Connect motor and heater leads to leads from the control panel and connect thermostat to terminals in panel per print. C. Connect wires from microswitch to terminals in control panel per print. D. Check rotation of blower wheels. Switch leads if necessary to correct. E. The door microswitch has normally closed contacts. The contacts open when the door shuts depressing the plunger, turning the Air Curtain off. |
|
|
|
TYPICAL INSTALLATION OF METAL AIR CURTAINS FOR DRUM TYPE ROLL-UP DOORS
|
|
 |
|
|
TYPICAL INSTALLATION FOR VERTICAL LIFT TRACK DOORS
|
|
 |
|
|
|
TYPICAL INSTALLATION FOR OVERHEAD MOUNTING
|
|
|
|
|
 |
|
|
Electric Heated Air Curtains, Air Curtain, Air Curtain Door, Air Curtain Heater, Air Curtains, Air Doors, Door Air Curtains, Heat Curtains, Mars Air Curtain, Mars Air Door, Warm Air Curtains, and Insect Barrier from your source for material handling equipment.
|
|